Operation
4-3
Part 1604857-04
E 2014 Nordson Corporation
Re-Coat
Metallics
Deep Recesses
Figure 4-2 Select Charge Modes
NOTE: If you press the STD/AFC selection button while using a Select
Charge mode, the controller switches to Classic or Custom mode.
Custom Electrostatic Mode
Custom Mode is the factory default electrostatic mode.
In Custom mode, both kV output and microampere A) output limits can be
adjusted independently. Both the kV and AFC LEDs light to indicate that the
controller is in this mode.
Use the View button
to toggle the display between kV and A. Press
the + or buttons to select the desired setpoints. The longer a button is
pressed the faster the units change.
S The valid AFC range is 5100 A.
S The valid STD range is 0 or 25100 kV.
Classic Electrostatic Mode
Classic Mode is the optional electrostatic mode. The controller must be
configured to use this mode; refer to page 3-16 for configuration
instructions.
In Classic mode you can choose to control kV (STD) output or A (AFC)
output, but not both at the same time.
Classic Standard (STD) Mode
See Figure 4-3. Use the STD mode to set the no-load output voltage (kV).
1. Press the STD/AFC button
to toggle between STD and AFC.
The LEDs light to show which is selected. Select STD. The STD LED
will light.
2. Press the View button
to toggle the display between kV and A.
Press the + or buttons to select the desired kV setpoint. The longer a
button is pressed the faster the units change.
The valid STD range is 0 or 25100 kV.