EasyManua.ls Logo

Nordson Encore LT - Switch Installation (Contd)

Nordson Encore LT
92 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Repair
6-8
Part 1604857-04
E 2014 Nordson Corporation
Switch Installation (contd)
3. See Figure 6-10. Straighten the ribbon cable, then bend the pull tab at
the top of the switch so that it is perpendicular to the switch.
Figure 6-10 Installing the Trigger Switch Step 3
4. See Figure 6-11. Peel the adhesive release liner from the switch.
5. Carefully install the switch, pull tab up, against the bottom and right
edges of the trigger recess.
6. Make sure the ribbon cable is not trapped or pinched, then press the
switch against the back of the recess. Run your finger up and down on
the switch to ensure it is securely adhered to the handle.
Figure 6-11 Installing the Trigger Switch Step 4
7. See Figure 6-7. Install the purge trigger (19) into the spray trigger (20)
with the gusset oriented upward as shown. Do not install the purge
trigger upside down.
8. Position the triggers in the handle and hold them in place while pressing
the axle (23A) through the handle and triggers until the head of the axle
is flush with the handle. The axle will snap into place when properly
installed.
9. Connect the trigger switch connector to the round cable connector, then
tuck the connectors back up to the handle.
10. Re-install the ground cover as described in Cable Installation steps 57
on page 6-6.

Table of Contents

Other manuals for Nordson Encore LT

Related product manuals