Operation
4-12
Part 1604857-04
E 2014 Nordson Corporation
Installing the Optional Pattern Adjuster Kit
An optional pattern adjuster kit with integral conical nozzle can be installed
in place of a standard flat spray or conical nozzle.
NOTE: Deflectors are not included with the pattern adjuster kit; they must
be ordered separately. The 38-mm deflector cannot be used with the kit.
1. Remove the deflector, nozzle nut, and conical nozzle, or the nozzle nut
and flat spray nozzle.
2. Blow off the electrode assembly.
3. See Figure 4-9. Install the integral conical nozzle onto the electrode
assembly and screw the nozzle nut clockwise until finger-tight
4. Install a 16, 19, or 26-mm deflector onto the electrode holder.
NOTE: To clean the pattern adjuster, use the Recommended Cleaning
Procedure for Powder Contact Parts on page 4-13.
Deflector
Electrode
Assembly
Pattern
Adjuster Kit
Electrode Holder
Figure 4-9 Pattern Adjuster Kit Installation
Shutdown
1. Purge the spray gun by pressing the Purge button until no more powder
is blown from the gun.
2. Press the Enable/Disable button to turn off the spray gun and put the
controller to sleep.
3. Turn off the system air supply and relieve the system air pressure.
4. If shutting down for the night or a longer period of time, disconnect
power to the controller.
5. Perform the Daily Maintenance procedures on page 4-13.