CHARGER / DISCAHRGER UL10 OPERATION MAUNAL
12 © NorTec Electronics 2014
4 Ratings
4.1 Input & Output Parameters
input voltage 220 V + 10% (single-phase alternating)
input frequency 45-60 Hz
input power 2000 VА
external mains protection 16 А, mean inertia
fan power about 100 / 300 l/min
charge current range 0.5 – 40 А
discharge current range 0.5 – 40 А
charge voltage range 0.1 – 40 V
discharge voltage range 0.1 – 40 V
voltage error < 0.1 % of rated parameter plus ±5 discharge
current power error < 3 % of rated parameter plus ±5 discharge
temperature error < ±2
С
Insulation VDE 0160, class 1
Protection type IP 54
working temperature -20
С to +45 С
Weight about 50 kg (in 19” body, without battery cable)
Dimensions width 400 mm, height 504 mm, depth 242 mm
Free space for exhaust > 50 mm
4.2 Working temperature range
The device operation is guaranteed within the temperature range -20
С to + 45 С.
The accuracy of the readings of the indicator and printed out discharge and charge parameters
correspond to the above indicated.
The accuracy of output values within the temperature range -20
оС to +45 ОС is guaranteed for
2 years since the time of delivery of the device.