EasyManua.ls Logo

Nortec UL10 - Program 110. Commissioning - Air-Tight Aircraft Lead Acid Battery

Nortec UL10
74 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
CHARGER / DISCAHRGER UL10 OPERATION MAUNAL
© NorTec Electronics 2014
43
7.7 Program 110. Commissioning – air-tight aircraft lead acid battery
Stage name Maximum
duration
Program number 110
Operation number 1
Operation type Commissioning
Battery type Lead acid
Manufacturing process Gel / absorbed electrolyte
Access to valves unavailable
Battery type 10
Minimum battery capacity 2 Ah
Maximum battery capacity 200 Ah
Minimum battery voltage 2 V
Maximum battery voltage 30 V
Maximum number of batteries 15
Stage 1 (S1) Discharge Discharge current а =xС (A) x= 0.2
Stage 1 (S1) Discharge Discharge depth V/battery 1,5
Discharge voltage <1.5 V Error
Message
Use program
410
Stage 2 (S2) I-Charge Current = xС (A) x= 0.4 8h
Stage 2 (S2) I-Charge Umax = V/battery 2.4 8h
Stage 3 (S3) U-Charge Umax = V/battery 2.4 8h
Stage 3 (S3) U-Charge Ia = xС (A) x= 0.04 8h
Note: when the maximum output current of the device is exceeded the maximum time para-
meters change accordingly.

Table of Contents