CHARGER / DISCAHRGER UL10 OPERATION MAUNAL
38 © NorTec Electronics 2014
7.2 Program 10. Discharge – air-tight aircraft lead acid battery
Stage name Maximum
duration
Program number 10
Operation number 0
Operation type Discharge
Battery type Lead acid Manufacturing
process Gel / absorbed
electrolyte
Access to valves unavailable
Battery type 10
Minimum battery capacity 2 Аh
Maximum battery capacity 200 Аh
Minimum battery voltage 2
Maximum battery voltage 30
Maximum number of batteries 15
Stage 1 (S1) Discharge Current = xС (A) x=0.2 max 6 h
Stage 1 (S1) Discharge Discharge depth V/battery 1.5
Stage 1 (S1) Discharge Time t=1min – 999min