CHARGER / DISCAHRGER UL10 OPERATION MAUNAL
© NorTec Electronics 2014
53
7.17 Program 231. Charging – aircraft nickel-cadmium battery type НКБН
Stage name Maximum
duration
Program number 231
Operation number 2
Operation type Charging
Battery type Nickel-cadmium
Manufacturing process used plates
Access to valves open, type НКБН
Battery type 31
Minimum battery capacity 2 Ah
Maximum battery capacity 50 Ah
Minimum battery voltage 1.2 V
Maximum battery voltage 31.2 V
Maximum number of batteries 25
Stage 1 (S1) I-Charge 1 Current = xС (A) х = 0.4 180 min
Stage 1 (S1) I-Charge 1 Umax = V/battery unlimited
Stage 2 (S2) Topping charge 1 I а= xС (A) 0.2 120 min
Stage 2 (S2) Topping charge 1 Electrolyte level Sound signal 105 min
equalization
Note: this program can only be used with discharged batteries!