CHARGER / DISCAHRGER UL10 OPERATION MAUNAL
50 © NorTec Electronics 2014
7.14 Program 220. Charging – aircraft nickel-cadmium battery
Stage name Maximum
duration
Program number 220
Operation number 2
Operation type Charging
Battery type Nickel-cadmium
Manufacturing process Fused electrodes
Access to valves Open
Battery type 20
Minimum battery capacity 4 Ah
Maximum battery capacity 50 Ah
Minimum battery Voltage 1,2 V
Maximum battery Voltage 31,2 V
Maximum number of Batteries 26
Stage 1 (S1) I-Charge 1 Current = xС (A) х = 1 72 min
Stage 1 (S1) I-Charge 1 Umax = V/battery 1.55 72 min
Stage 2 (S2) Topping charge 1 I а= xС (A) х = 0.2 90 min
Stage 2 (S2) Topping charge 1 Electrolyte level Sound signal 75 min
equalization

Table of Contents