CHARGER / DISCAHRGER UL10 OPERATION MAUNAL
48 © NorTec Electronics 2014
7.12 Program 211. Charging – Pb battery sealed commercial
Stage name Maximum
duration
Program number 211
Operation number 2
Operation type Charging
Battery type Lead acid
Manufacturing process Gel / absorbed
electrolyte
Access to valves unavailable
Battery type 11
Minimum battery capacity 2 Ah
Maximum battery capacity 200 Ah
Minimum battery voltage 2 V
Maximum battery voltage 30 V
Maximum number of batteries 15
For voltages < 2.25 V/battery
Stage 1 (S1) Precharge Umax = V/battery 2.4 2 h
Stage 1 (S1) Precharge Iа = xС (A) 0.36 2 h
Stage 2 (S2) I-Charge Current = xС (A) 0.36 8 h
Stage 2 (S2) I-Charge Umax = V/battery 2.4 8 h
Stage 3 (S3) U-Charge Umax = V/battery 2.4 8 h
Stage 3 (S3) U-Charge I а= xС (A) 0.02 8 h
Stage 4 (S4) U-Charge Voltage = V/battery 2.4 2 h
Note: when the maximum output current of the device is exceeded the maximum time para-
meters change accordingly.