EasyManua.ls Logo

Nortec UL10 - Program 420. Maintenance - Enclosed Aircraft Nickel-Cadmium Battery

Nortec UL10
74 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
CHARGER / DISCAHRGER UL10 OPERATION MAUNAL
58 © NorTec Electronics 2014
7.21 Program 420. Maintenance – enclosed aircraft nickel-cadmium battery
Stage name Maximum
duration
Program number 420
Operation number 4
Operation type Maintenance
Battery type Nickel-cadmium
Manufacturing process Fused electrodes
Access to valves open
Battery type 20
Minimum battery capacity 4 Ah
Maximum battery capacity 50 Ah
Minimum battery voltage 1,2 V
Maximum battery voltage 31,2 V
Maximum number of batteries 26
Stage 1 (S1) Discharge 1 Discharge current х = 1 max. 6 min.
а = xС (A)
Stage 1 (S1) Discharge 1 Discharge depth 1 max. 6 min.
V/battery
Stage 2 (S2) I-Charge 1 Current = xС (A) х = 1 max. 72 min.
Stage 2 (S2) I-Charge 1 Umax = V/battery 1.55 max. 72 min.
Stage 3 (S3) Topping charge 1 Current = xС (A) х = 0.1 120 min.
Stage 4 (S4) Discharge 2 Discharge current х = 1 1 h
а = xС (A)
Stage 4 (S4) Discharge 2 Discharge depth 0.5 1 h
V/battery
Stage 5 (S5) I-Charge 2 Current = xС (A) х = 1 1 h
Stage 5 (S5) I-Charge 2 Umax = V/battery 1.55 1 h
Stage 6 (S6) Topping charge 2 Current = xС (A) х = 0.2 90 min.
Stage 6 (S6) Topping charge 2 Measurement of Sound signal 75 min.
voltages of individual
batteries
Stage 6 (S6) Topping charge 2 Electrolyte level Sound signal 75 min.
equalization

Table of Contents