Chapter 11. M.2 Boot Drive Riser
Assembly Replacement
This chapter applies when both M.2 OS drives need to be replaced. In that case, a replacement riser
assembly (which includes both M.2 NVMe drives) should be ordered.
11.1. M.2 Boot Drive Riser Assembly
Replacement Overview
This is a high-level overview of the procedure to replace the boot drive riser assembly.
1. Conrm that both M.2 drives cannot be reached and need to be replaced.
2. Get replacement M.2 riser assembly from NVIDIA Enterprise Support.
3. Power down the system.
4. Label all motherboard tray cables and unplug them.
5. Slide out the motherboard tray and open the motherboard tray lid.
6. Pull out the M.2 riser assembly with both M.2 disks attached.
7. Install the new M.2 riser assembly with both M.2 disks attached..
8. Close the lid on the motherboard tray.
9. Slide the motherboard tray into the system.
10. Plug in all cables using the labels as a reference.
11. Power on the system.
12. Re-install the OS and conrm the system is healthy.
13. Ship back the failed unit to NVIDIA Enterprise Support using the packaging provided.
47

Table of Contents

Other manuals for Nvidia DGX A100

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Nvidia DGX A100 and is the answer not in the manual?

Nvidia DGX A100 Specifications

General IconGeneral
BrandNvidia
ModelDGX A100
CategoryComputer Hardware
LanguageEnglish

Related product manuals