TROUBLESHOOTING (TO BE PERFORMED BY TRAINED SERVICE PROVIDERS ONLY), CONTINUED
44
CONDITION TROUBLESHOOTING
No Case Lights Are
Working
Follow previous pages System Not Operating instructions.
Check voltage at LED driver. If voltage is entering but not exiting, LED driver may
be faulty.
Check connection at case rear (from field wiring box) for voltage.
Case Light Is Not
Working
Follow previous pages System Not Operating instructions.
If case light still do not come on, call SCC Technical Service phone number
(listed on last page of this operating manual).
Control Display Is
Flashing
See your cases thermostat label (near temperature controller) for your models
required settings.
Case Is Not Holding
Temperature
If a large amount of warm product was added to the case, it will take time for the
temperature to adjust. Unit needs product to be pre-chilled.
Temperature changes during defrost mode but will return to normal. Fourth LED
(on temperature controller) will indicate defrost cycle in progress.
Check that case is not in sun or near a heat or air-conditioning vent.
If case is located near front doors, temperature fluctuation can hinder units ability
to maintain temperature.
Check that condenser coil has been cleaned.
Check air grilles for obstructions.
Check sight glass for flashing and/or low charge.
Check Set Point Temperature; it may be adjusted too high.
Condensing Unit Is
Not Operating
Check that the power is turned on.
Determine if temperature controller settings are properly set. See your cases
serial label for your models specified settings. See SERIAL LABEL LOCATION
& INFORMATION LISTED / TECH INFO & SERVICE section in manual for label
location, etc.