PIZZA OVEN mod. TL
CHAPTER 6 COMMANDS AND USE
Page 59
6.4.1. "ALARMS" list
Below is the list of "ALARMS"
ALARM
RESTORE
IMAGE
ENGINE BLOCK
ALARM
When you see the alarm "engine block" make sure that the
emergency mushroom is unlocked.
Turn off the oven and repeat the operation.
If the alarm is raised again, call the technical support service.
SHORT CIRCUIT
PROBE
It reports that the chamber temperature probe is in short-
circuiting.
The oven is turned off.
Call the technical support service for the probe replacement.
PROBE INTERRUPTED
OR DISCONNECTED
It reports that the chamber temperature probe is interrupted or
disconnected.
Il oven is turned off.
Call the technical support service for the control and/or
replacement of the probe.
CHAMBER OVER
HEATING
It reports that the temperature in the chamber has exceeded
500°C.
The heating of the oven is turned off.
Turn off the oven, wait for the chamber to cool down
and repeat the operation.
If the alarm is raised again, call the technical support service.
OVER HEATING
TQ It reports that the temperature of the power card heatsink
has exceeded 70°C.
Turn off the oven and check that the cooling fans of the
technical compartment are working properly.
TS Indicates that the security thermostat intervened.
Call Technical Support.
REMOTE CONTROL
SWITCH ALARM
Indicates that the general remote control switch is faulty.
Call Technical Support.