2HA/2HB
1-3-48
U407
Adjusting the leading edge registration for memory image printing
Description
Adjusts the leading edge registration during memory copying.
Purpose
Make the adjustment if there is a regular error between the leading edges of the copy image and original dur-
ing memory copying.
Caution
Before making this adjustment, ensure that the following adjustments have been made in maintenance mode
Adjustment
1. Press the start key.
2. Press the interrupt key.
3. Place an original and press the start key to make a test copy.
4. Change the setting value using the zoom +/- keys.
For copy example 1, increase the value.
For copy example 2, decrease the value.
Figure 1-3-18
5. Press the start key. The value is set.
Completion
Press the stop/clear key. The indication for selecting a maintenance item No. appears.
Maintenance
item No.
Description
U034
(P.1-3-12)
U053
(P.1-3-16)
U065
(P.1-3-18)
U066
(P.1-3-19)
U407
Description
Setting
range
Initial
setting
Change in
value per step
Leading edge registration for memory image
printing
-10.0 to 10.0 0.0 1.0 mm
Original Copy
example 1
Copy
example 2