4.
Create code for the standard program.
Add the code to change the command velocity.
When the SS2 and SOS functions are active, reduce the command velocity to 0 r/min.
When the SS2 and SOS functions are inactive, increase the command velocity to 600
r/min.
0 [r/min] (0% of command
velocity) when the SS2 and
SOS functions are active.
600 [r/min] (100% of command
velocity) when the SS2 and
SOS functions are inactive.