Power supply
system
Standard applicable
motor (kW)
Inverter Model
HHD/HD/HND/ND
modes
Tightening torque
lb-in (Nm)
Wire size AWG (mm
2
)
Main Terminal
Inverter's
grounding
Control circuit
auxiliary input
Main circuit copper wire
G
Control circuit
auxiliary input
L1/R, L2/S, L3/T U, V, W
60°C Cu Wire
75°C Cu Wire
Remarks
60°C Cu Wire
75°C Cu Wire
Remarks
Inverter's
grounding
Thre
e-
phas
e
400
V
5.5 3G3M1-
A4040-
ECT
ND 10.6
(1.2)
15.9
(1.8)
- 12
(3.3)
12
(3.3)
*3
14
(2.1)
14
(2.1)
*3
10
(5.3)
-
3G3M1-
A4040-
ECT
HD/
HND
3G3M1-
A4055-
ECT
HHD 27
(3)
27
(3)
7.5 3G3M1-
A4055-
ECT
HD/
HND
27
(3)
27
(3)
- 10
(5.3)
10
(5.3)
*3
12
(3.3)
12
(3.3)
*3
10
(5.3)
-
3G3M1-
A4075-
ECT
HHD
11 3G3M1-
A4055-
ECT
ND 8
(8.4)
8
(8.4)
10
(5.3)
10
(5.3)
8
(8.4)
3G3M1-
A4075-
ECT
HD/
HND
3G3M1-
A41
10-
ECT
HHD
51.3
(5.8)
51.3
(5.8)
15 3G3M1-
A4075-
ECT
ND 27
(3)
27
(3)
6
(13.3
)
3G3M1-
A4110-
ECT
HD/
HND
51.3
(5.8)
51.3
(5.8)
8
(8.4)
8
(8.4)
3G3M1-
A4150-
ECT
HHD
18.5
3G3M1-
A4110-
ECT
ND 6
(13.3
)
6
(13.3
)
6
(13.3
)
14
(2.1)
*
1*2
3G3M1-
A4150-
ECT
HD/
HND
3G3M1-
A4185-
ECT
HHD 10.6
(1.2)
6
(13.3
)