Parameter No.
Parameter name
1st control motor 2nd control motor
3004Hex-2CHex 301FHex-2FHex Overload Protect Function Selection
3004Hex-2DHex 301FHex-30Hex Overload Protect Level
3005Hex-26Hex 3005Hex-39Hex Overload Early Warning Detection Level
3005Hex-27Hex 3005Hex-38Hex Overload Early Warning Detection Timer
3005Hex-28Hex 3009Hex-3EHex
Display Coefficient 1 for Transport Time / Auxiliary Display Coeffi-
cient 1 for Speed Monitor
3005Hex-33Hex 3009Hex-3DHex Display coefficient for speed monitor
301FHex-0DHex 301FHex-0EHex Torque Boost Function Selection
3004Hex-0AHex 3009Hex-06Hex Manual Torque Boost Voltage
301FHex-17Hex 301FHex-18Hex AVR Function Selection
3006Hex-36Hex 3006Hex-37Hex
Input Terminal [AI1, AI2] Normal/Inverse Operation for 1st Fre-
quency Command
3007Hex-02Hex 3009Hex-10Hex Pole Number
3007Hex-03Hex 3009Hex-11Hex Motor capacity
3007Hex-04Hex 3009Hex-12Hex Motor Rated Current
3007Hex-05Hex 3009Hex-13Hex Auto Tuning Function Selection
3007Hex-06Hex 3009Hex-14Hex Online tuning Function Selection
3007Hex-07Hex 3009Hex-15Hex Motor Armature Resistance
3007Hex-08Hex 3009Hex-16Hex Motor Parameter %R1
3007Hex-09Hex 3009Hex-17Hex Motor Parameter %X
3007Hex-36Hex 3009Hex-36Hex Motor %X Correction Factor
3007Hex-0AHex 3009Hex-18Hex Slip Compensation Gain for Driving
3007Hex-0BHex 3009Hex-19Hex Slip Compensation Response Time
3007Hex-0CHex 3009Hex-1AHex Slip Compensation Gain for Braking
3007Hex-0DHex 3009Hex-1BHex Rated Slip Frequency
3007Hex-0EHex 3009Hex-1CHex Iron Loss Factor 1
3007Hex-11Hex 3009Hex-1FHex Magnetic Saturation Factor 1
3007Hex-12Hex 3009Hex-20Hex Magnetic Saturation Factor 2
3007Hex-13Hex 3009Hex-21Hex Magnetic Saturation Factor 3
3007Hex-14Hex 3009Hex-22Hex Magnetic Saturation Factor 4
3007Hex-15Hex 3009Hex-23Hex Magnetic Saturation Factor 5
3007Hex-38Hex 3009Hex-38Hex Torque Current for Vector Control
3007Hex-39Hex 3009Hex-39Hex Induced Voltage Factor for Vector Control
• The following parameters are enabled only when 1st control is selected. When 2nd control is select-
ed, this control operates by setting the following parameters.
Parameter No. Parameter name
3004Hex-13Hex Input Terminal [AI1, AI2] Bias for 1st Frequency Command
3006Hex-33Hex Input Terminal [AI1, AI2] Bias Analog Input for 1st Frequency Command
3020Hex-60Hex DC Injection Braking Startup Time
3008Hex-4FHex 1st Motor Maintenance Interval
3008Hex-50Hex 1st Preset Startup Count for Motor Maintenance
3003Hex-52Hex 1st Remaining Time before the Next Motor Maintenance
3003Hex-56Hex 1st Remaining Startup Times before the Next Motor Maintenance
3007Hex-1FHex 1st PM Motor Starting Method
3007Hex-3DHex 1st PM Motor Armature Resistance
6 Basic Settings
6-48
M1 Series EtherCAT Type User’s Manual (I670)