Alarm
code
Alarm
subcode
Name Description  Check point and remedy reference
01 Hex
(during ac-
celeration)
(0C1)
02 Hex
(during de-
celeration)
(0C2)
03 Hex
(during con-
stant speed
operation)
(0C3)
(0Cn)
0000 Hex
Instantaneous
overcurrent
(1) Short in inverter
output
Remove wiring from the inverter output termi-
nal (U, V, W), and measure the resistance
between motor wiring phases. Check for
phases with very low resistance.
Remove the shorted section (including
replacement of wiring, relay terminals,
and motors)
If an overcurrent is displayed when run with
wiring removed from the inverter output ter-
minal (U, V, W).
This indicates an inverter fault possibili-
ty. Replace the inverter
.
(2) Inverter output
terminal has a
ground fault
Remove wiring from the inverter output termi-
nal (U, V, W), and perform a megger test.
Remove ground faults (including re-
placement of wiring, relay terminals, and
motors).
If an overcurrent is displayed when run with
wiring removed from the inverter output ter-
minal (U, V, W).
This indicates an inverter fault possibili-
ty. Replace the inverter
.
(3) High load Measure current going in to the motor, estab-
lish current trends, and determine if this is
larger than the load calculation values de-
signed in to the system.
If overload, either decrease the load or
increase the inverter capacity.
Check current trends, and check if there are
rapid changes in current.
If the current changes rapidly, either de-
crease the load or increase the inverter
capacity.
Enable instantaneous overcurrent limit-
ing (3008Hex-0DHex = 1).
(4) Large torque
boost (If manual tor-
que boost
(3004Hex-26Hex* =
0, 1, 3, 4))
Check if the current drops when 1st Manual
Torque Boost V
oltage (3004Hex-0AHex*) is
lowered, or if there is a stall.
If it is determined that there is no stall,
lower 3004Hex-0AHex*.
9 Troubleshooting
9-15
M1 Series EtherCAT Type User’s Manual (I670)
9-1 Alarm Display and Remedies
9
9-1-2 Alarm Code List

Table of Contents

Related product manuals