EasyManua.ls Logo

Omron 3G3M1-A4004-ECT - Page 658

Omron 3G3M1-A4004-ECT
850 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Index
(hex)
Sub-
index
(hex)
Pa-
rame-
ter No.
Function name Monitor or data range
Default
data
Set-
ting
dur-
ing
RUN
Unit
PDO
map
16 F21 1st DC Injection
Braking Level
V/f DTV
PG V/f PG DTV
SLV PGV
PM SLV PM PGV
0 to 100 (HHD mode)
0 to 80 (HND/HD mode)
0 to 60 (ND mode)
Based on inverter rated current
0
% Possible
17 F22 1st DC Injection
Braking Time
V/f DTV
PG V/f PG DTV
SLV PGV
PM SLV PM PGV
0.00: Disable
0.01 to 30.00
0.00
s Possible
18 F23 1st Starting Fre-
quency
V/f DTV
PG V/f PG DTV
SLV PGV
PM SLV PM PGV
0.0 to 60.0
0.5
Hz Possible
19 F24 1st Starting Fre-
quency 1 Holding
Time
V/f DTV
PG V/f PG DTV
SLV PGV
PM SLV PM PGV
0.00 to 10.00
0.00
s Possible
1A F25 1st Stop Fre-
quency
V/f DTV
PG V/f PG DTV
SLV PGV
PM SLV PM PGV
0.0 to 60.0
0.2
Hz Possible
1B F26 Carrier Frequen-
cy
V/f DTV
PG V/f PG DTV
SLV PGV
PM SLV PM PGV
0: 0.75
1 to 16
2
kHz Possible
1C F27 Motor Sound
Tone
V/f DTV
PG V/f PG DTV
SLV PGV
PM SLV PM PGV
0: Level 0 (Disable)
1: Level 1
2: Level 2
3: Level 3
0
--- Possible
26 F37 1st V/f Charac-
teristics Selection
V/f DTV
PG V/f PG DTV
SLV PGV
PM SLV PM PGV
0: Variable torque load
1: Constant torque load
1 --- --- Possible
27 F38 1st Stop Fre-
quency Detection
Method Selection
V/f DTV
PG V/f PG DTV
SLV PGV
PM SLV PM PGV
0: Output frequency, Detected speed
1: Frequency reference
0 --- --- Possible
Appendices
A-112
M1 Series EtherCAT Type User’s Manual (I670)

Table of Contents

Related product manuals