EasyManua.ls Logo

Omron 3G3M1-A4004-ECT - Page 657

Omron 3G3M1-A4004-ECT
850 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Index
(hex)
Sub-
index
(hex)
Pa-
rame-
ter No.
Function name Monitor or data range
Default
data
Set-
ting
dur-
ing
RUN
Unit
PDO
map
0B F10 1st Motor Elec-
tronic Thermal
Characteristic
Selection
V/f DTV
PG V/f PG DTV
SLV PGV
PM SLV PM PGV
1: For a general-purpose motor with
shaft-driven cooling fan
2: For an inverter-driven motor non-
ventilated motor or motor with sepa-
rately powered cooling fan
1
--- Possible
0C F11 1st Motor Elec-
tronic Thermal
Level
V/f DTV
PG V/f PG DTV
SLV PGV
PM SLV PM PGV
0.00: Disable
0.01 to 118.8
Setting range from 1% (HHD) to
135% (ND) of the rated inverter cur-
rent
21
A
Possible
0D F12 1st Motor Elec-
tronic Thermal
Time Constant
V/f DTV
PG V/f PG DTV
SLV PGV
PM SLV PM PGV
0.5 to 75.0
5
min Possible
0F F14 Power Interrup-
tion Restart
Mode Selection
V/f DTV
PG V/f PG DTV
SLV PGV
PM SLV PM PGV
0: Immediately trip (Free run stop)
1: Trip after a recovery from power
failure (Free run stop)
2: T
rip after decelerate-to-stop
3: Continue to run
4: Restart at the frequency selected
by E152
6: Decelerate-to-stop (w/o trip)
1
--- Possible
10 F15 1st Frequency
Upper Limit
V/f DTV
PG V/f PG DTV
SLV PGV
PM SLV PM PGV
0.00 to 590.00
70.00
Hz Possible
11 F16 1st Frequency
Lower Limit
V/f DTV
PG V/f PG DTV
SLV PGV
PM SLV PM PGV
0.00 to 590.00
0.00
Hz Possible
13 F18 Input Terminal
[AI1, AI2] Bias for
1st Frequency
Command
V/f DTV
PG V/f PG DTV
SLV PGV
PM SLV PM PGV
-100.00 to 100.00
0.00
% Possible
15 F20 1st DC Injection
Braking Start
Frequency
V/f DTV
PG V/f PG DTV
SLV PGV
PM SLV PM PGV
0.0 to 60.0
0.0
Hz Possible
Appendices
A-111
M1 Series EtherCAT Type User’s Manual (I670)
A-4 Lists of Manufacturer Specific Objects 2
(Inverter Parameters)
A
A-4-5 F Group Parameter List (Basic Functions)

Table of Contents

Related product manuals