Event name Number of Startups Over Event code 684C0000 hex
Meaning The cumulative number of startups of the motor reached the set count for maintenance.
Source EtherCAT Master Function Mod-
ule
Source details Slave Detection tim-
ing
Continuously
Error attrib-
utes
Level Observation Recovery Automatic re-
covery
Log category System log
Effects User program Continues. Operation Not affected.
Indicators EtherCAT NET RUN EtherCAT NET ERR EtherCAT LINK/ACT
--- --- ---
System-de-
fined varia-
bles
Variable Data type Name
None None None
Cause and
correction
Assumed cause Correction Prevention
(1) Number of Startups Over Check the cumulative startup
count in 1st Startup count for
motor (3008-2D hex).
→ After maintenance, reset the
value of 1st Startup count for
motor (3008-2D hex) to 0.
None
Attached in-
formation
None
Precautions/
Remarks
None
Appendices
A-283
M1 Series EtherCAT Type User’s Manual (I670)
A-5 Sysmac Error Status Codes
A
A-5-2 Error Descriptions

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Omron 3G3M1-A4004-ECT and is the answer not in the manual?

Omron 3G3M1-A4004-ECT Specifications

General IconGeneral
BrandOmron
Model3G3M1-A4004-ECT
CategoryInverter
LanguageEnglish

Related product manuals