2nd Slip Compensation Gain for Braking (3009Hex-1AHex)
2nd Rated Slip Frequency (3009Hex-1BHex)
2nd Iron Loss Factor 1 (3009Hex-1CHex)
2nd Magnetic Saturation Factor 1 (3009Hex-1FHex)
2nd Magnetic Saturation Factor 2 (3009Hex-20Hex)
2nd Magnetic Saturation Factor 3 (3009Hex-21Hex)
2nd Magnetic Saturation Factor 4 (3009Hex-22Hex)
2nd Magnetic Saturation Factor 5 (3009Hex-23Hex)
Torque Current for 2nd V
ector Control (3009Hex-38Hex)
Induced Voltage Factor for 2nd Vector Control (3009Hex-39Hex)
Restore User Defined Data (3008Hex-04Hex= 4)
When “4: Restore user defined data” is set to Data Initialization (3008Hex-04Hex), parameters are
initialized using the user preference dataset saved at User Preference Dataset Registration
(3020Hex-5EHex). When there are no user preference dataset, parameters are initialized using fac-
tory defaults. (Same operation as when Data Initialization (3008Hex-04Hex) is set to 1).
User preference dataset saved by User Preference Dataset Registration (3020Hex-5EHex) are not
initialized. (Refer to 6-1-2 User Preference Dataset (Registration/Protection) on page
6-6.)
The following parameters are not initialized.
Main Circuit Capacitor Service Life Coefficient (Measurement Value) (3008Hex-2BHex)
Main Circuit Capacitor Service Life Coefficient (Initial Value) (3008Hex-30Hex)
Service Life of Main Circuit Capacitor Remaining Time (3008Hex-4EHex)
Cumulative Run Time of Cooling Fan (3008Hex-2CHex)
Cumulative Run Time of Capacitors on Printed Circuit Boards (3008Hex-31Hex)
1st Startup Count for Motor (3008Hex-2DHex)
2nd Startup Counter for Motor (3009Hex-35Hex)
1st Cumulative Motor Run Time (3008Hex-5FHex)
2nd Cumulative Motor Run Time (3009Hex-34Hex)
User Preference Dataset Protection Function Selection (3020Hex-5FHex)
Monitor Exclusive Parameters (M, W Parameters)
Initialize All Parameters (Except I/O and Communications)
(3008Hex-04Hex = 5)
When “5: Initialize all parameters (except I/O and communications)” is set to Data Initialization
(3008Hex-04Hex), the following parameters excluding I/O and communications are initialized to their
factory defaults.
Input Terminal [DI1] to [DI7] Function Selection (3005Hex-02Hex to 3005Hex-06Hex,
3005Hex-63Hex, 3005Hex-64Hex)
Output T
erminal [DO1] Function Selection (3005Hex-15Hex)
Output Terminal [ROA, ROB] Function Selection (3005Hex-1CHex)
Also, the following parameters are not initialized.
6 Basic Settings
6-5
M1 Series EtherCAT Type User’s Manual (I670)
6-1 Data Initialization
6
6-1-1 Data Initialization