Setting list
A-23
Appendix
CompoWay/F
Setting data
Attributes
Variable type
Address Address
Modbus
Character Setting (monitor) value Character
Default
value
Decimal point
position
Units
Set value
CF 0000
0001
0002
0003
0004
0005
0006
0007
0008
0009
000A
000B
000C
000D
000E
000F
0010
0F00
0F02
0F04
0F06
0F08
0F0A
0F0C
0F0E
0F10
0F12
0F14
0F16
0F18
0F1A
0F1C
0F1E
0F20
alt1
a1lt
alh1
alt2
a2lt
alh2
alt3
a3lt
alh3
alt4
a4lt
alh4
rest
sb1n
sb2n
sb3n
sb4n
H'00000000: No alarm (0)
H'00000001: Upper-and lower-limit alarm (1)
H'00000002: Upper-limit alarm (2)
H'00000003: Lower-limit alarm (3)
H'00000004:
Upper-and lower-limit of range alarm (4)
H'00000005: Upper-and lower-limit alarm with standby sequence (5)
H'00000006: Upper-limit alarm with standby sequence (6)
H'00000007: Lower-limit alarm with standby sequence (7)
H'00000008:Absolute-value upper-limit alarm (8)
H'00000009: Absolute-value lower-limit alarm (9)
H'0000000A: Absolute-value upper-limit with standby sequence (10)
H'0000000B: Absolute-value lower-limit with standby sequence (11)
H'00000000: OFF (0)
H'00000001: ON (1)
H'00000001 to H'0000270F: 0.01 to 99.99
Same as alarm type 1
H'00000000: OFF (0)
H'00000001: ON (1)
H'00000001 to H'0000270F: 0.01 to 99.99
Same as alarm type 1
H'00000000: OFF (0)
H'00000001: ON (1)
H'00000001 to H'0000270F: 0.01 to 99.99
Same as alarm type 1
H'00000000: OFF (0)
H'00000001: ON (1)
H'00000001 to H'0000270F: 0.01 to 99.99
H'00000000: Condition A (0)
H'00000001: Condition B (1)
H'00000000: Excitation close in alarm: N-O (0)
H'00000001: Non-excitation open in alarm: N-C (1)
H'00000000: Excitation close in alarm: N-O (0)
H'00000001: Non-excitation open in alarm: N-C (1)
H'00000000: Excitation close in alarm: N-O (0)
H'00000001: Non-excitation open in alarm: N-C (1)
H'00000000: Excitation close in alarm: N-O (0)
H'00000001: Non-excitation open in alarm: N-C (1)
0 to 11
off, on
0.01 to 99.99
0 to 11
off, on
0.01 to 99.99
0 to 11
off, on
0.01 to 99.99
0 to 11
off, on
0.01 to 99.99
a, b
n-o, n-c
n-o, n-c
n-o, n-c
n-o, n-c
2
OFF
0.02
2
OFF
0.02
2
OFF
0.02
2
OFF
0.02
A
Excitation close
in alarm
Excitation close
in alarm
Excitation close
in alarm
Excitation close
in alarm
%FS
%FS
%FS
%FS
2
2
2
2
CH
CH
CH
CH
CH
CH
CH
CH
CH
CH
CH
CH
CH
Common
Common
Common
Common
Alarm 1 type
Alarm 1 latch
Alarm 1 hysteresis
Alarm 2 type
Alarm 2 latch
Alarm 2 hysteresis
Alarm 3 type
Alarm 3 latch
Alarm 3 hysteresis
Alarm 4 type
Alarm 4 latch
Alarm 4 hysteresis
Standby sequence restart
Auxiliary output 1 non-exciting
Auxiliary output 2 non-exciting
Auxiliary output 3 non-exciting
Auxiliary output 4 non-exciting
Alarm setting level
"H' -" indicated in set values (monitor values) are values set by communication (monitor).