EasyManua.ls Logo

Omron J1000 - Page 89

Omron J1000
232 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
V/f Pattern Examples
Table 5.11 Constant Torque Characteristics, Examples 0 to 3
Example 0
50 Hz
(default)
Example 1 60 Hz Example 2 60 Hz Example 3 72 Hz
0
12
200
1.3 2.5 50
16
Voltage (V)
Frequency (Hz)
0
12
16
200
1.5 3 60
Voltage (V)
Frequency (Hz)
0
12
16
200
1.5 3 6050
Voltage (V)
Frequency (Hz)
0
12
16
200
1.5 3 7260
Voltage (V)
Frequency (Hz)
Table 5.12 Derated Torque Characteristics, Examples 4 to 7
Example 4 50 Hz Example 5 50 Hz Example 6 60 Hz Example 7 60 Hz
0
8
200
1.3 25 50
35
Voltage (V)
Frequency (Hz)
0
9
200
1.3 25 50
50
Voltage (V)
Frequency (Hz)
0
8
200
1.5 30 60
35
Voltage (V)
Frequency (Hz)
0
9
200
1.5 30 60
50
Voltage (V)
Frequency (Hz)
Table 5.13 High Starting Torque, Examples 8 to 11
Example 8 50 Hz Example 9 50 Hz Example 10 60 Hz Example 11 60 Hz
0
12
200
1.3 2.5 50
19
Voltage (V)
Frequency (Hz)
0
13
200
1.3 2.5 50
24
Voltage (V)
Frequency (Hz)
0
12
200
1.5 3 60
19
Voltage (V)
Frequency (Hz)
0
15
200
1.5 3 60
24
Voltage (V)
Frequency (Hz)
Table 5.14 Rated Output Operation, Examples 12 to 14
Example 12
90 Hz Example 13 120 Hz Example 14 180 Hz
0
12
16
200
1.5 3 9060
Voltage (V)
Frequency (Hz)
0
12
16
200
1.5 3 12060
Voltage (V)
Frequency (Hz)
0
12
16
200
1.5 3 18060
Voltage (V)
Frequency (Hz)
5.5 E: Motor Parameters
SIEP C710606 33A OYMC AC Drive – J1000 User Manual
87
5
Parameter Details

Table of Contents

Other manuals for Omron J1000