13 Communications Performance and Communications Load
13-12
NJ-series CPU Unit Built-in EtherNet/IP Port User’s Manual (W506)
Method 2:
Change a Particular Devices Packet Interval (RPI) Setting:
The usage of capacity without multicast filtering can be adjusted for only a particular device
against the tag data link’s allowable bandwith by changing the packet intervals (RPI) settings for
all of the device’s connections together. In this case, the usage of capacity will also change for
the target devices of the connection for which the packet interval is changed.
(1) Click the Set Packet Interval (RPI) Button at the bottom of the Usage of Device Bandwidth
Dialog Box.
(2) The Set Packet Interval (RPI) Dialog Box will be displayed. In the
Target Device Area, dese-
lect the target devices that are not being adjusted by removing the check marks.
(3) Input a new RPI value, and click the OK Button.