14 Troubleshooting
14-32
NJ-series CPU Unit Built-in EtherNet/IP Port User’s Manual (W506)
Event name Tag Data Link Download Finished Event code 94020000 hex
Meaning Changing the tag data link settings finished.
Source EtherNet/IP Function Module Source details CIP Detection
timing
At user operation
Error attributes Level Information Recovery --- Log category Access
Effects User program Continues. Operation Not affected.
Indicators EtherNet/IP NET RUN EtherNet/IP NET ERR EtherNet/IP LINK/ACT
Flashes at 1-s intervals. --- ---
System-defined
variables
Variable Data type Name
None --- ---
Cause and
correction
Assumed cause Correction Prevention
Changing the tag data link settings
finished.
--- ---
Attached
information
Attached information 1: Controller status (01 hex: PROGRAM mode, 02 hex: RUN mode)
Precautions/
Remarks
None
Event name Tag Data Link Stopped Event code 94030000 hex
Meaning Tag data links were stopped by Network Configurator or manipulation of a system-defined variable. Or, the data link
table was downloaded from the Network Configurator again.
Source EtherNet/IP Function Module Source details CIP Detection
timing
At user operation
Error attributes Level Information Recovery --- Log category Access
Effects User program Continues. Operation Not affected.
Indicators EtherNet/IP NET RUN EtherNet/IP NET ERR EtherNet/IP LINK/ACT
Flashes at 1-s intervals. --- ---
System-defined
variables
Variable Data type Name
_EIP_TDLinkStopCmd BOOL Tag Data Link Communications Stop
Switch
Cause and
correction
Assumed cause Correction Prevention
Tag data links were stopped by Net-
work Configurator or manipulation of
a system-defined variable.
--- ---
Attached
information
Attached information 1: Controller status 01 hex: PROGRAM mode,
02 hex: RUN mode
Attached information 2: Operation method 01 hex: Operation from the Network Configurator,
02 hex: Operation with a system-defined variable
Precautions/
Remarks
None