Questions and Answers

  • R
    rhallSep 13, 2025
    What does '[With memory switch setting screen] Invalid Comm. Method' mean on Omron NT31 Touch terminals?
    • C
      Caroline PayneSep 14, 2025
      If your Omron Touch terminal displays the message '[With memory switch setting screen] Invalid Comm. Method', it indicates that protocol settings for serial port A and serial port B are mismatched. Refer to Possible Combinations of Communication Method Settings and set the protocol of serial port A and serial port B so that their settings are matched. Set serial port A to None when connecting the Support Tool and the host at the same time.
  • A
    Ann BellAug 31, 2025
    Why do the digits in numeral display come out as * on Omron Touch terminal?
    • W
      Wendy RiveraAug 31, 2025
      The digits in the numeral display come out as asterisks because the number of digits of a numeric value in a numeral memory table exceeds the set number. Confirm the values of the PLC words allocated to the numeral memory table. Allocate one PLC word to each numeral memory table.
  • J
    jfarmerAug 27, 2025
    What causes the buzzer to sound and the RUN LED to be OFF on Omron Touch terminal?
    • C
      Christy TurnerAug 27, 2025
      If the buzzer has sounded and the RUN LED is OFF on your Omron Touch terminal, it could be due to malfunction caused by external noise or the NT31/NT31 has developed trouble. Carry out grounding work or contact your OMRON service center.
  • K
    Karen RobertsSep 9, 2025
    Why window screen does not open on Omron NT31 Touch terminals?
    • K
      Kristen ChandlerSep 9, 2025
      If a window screen does not open on your Omron Touch terminal, it might be because bit 6 of the PT status control area (PT window opening) is set to 1 (ON). Set bit 6 to 0 (OFF).
  • J
    Joseph BrownSep 12, 2025
    What does '[No Comm. Protocol] Set the comm. Protocol by MAINTENANCE MODE' mean on Omron NT31 Touch terminals?
    • T
      Tyrone MartinSep 12, 2025
      If your Omron Touch terminal displays the message '[No Comm. Protocol] Set the comm. Protocol by MAINTENANCE MODE', it indicates that no communication protocol has been set, or the communication protocol and screen data type are mismatched. Using the memory switches, set the communication method to be used for communication with the host.
  • A
    Angela ObrienSep 2, 2025
    What to do if Omron Touch terminal displays '[Touch Panel is disconnected]'?
    • Y
      Yesenia MayerSep 2, 2025
      The '[Touch Panel is disconnected]' message indicates that the touch panel cable (film cable) inside the NT31/NT31C is disconnected. Contact your OMRON service center.
  • T
    Terri LaneSep 4, 2025
    How to fix Omron Touch terminals when the power LED fails to come ON?
    • C
      Courtney CainSep 4, 2025
      If the power LED on your Omron Touch terminal doesn't light up, first ensure the device is correctly connected to a power source. If the connection is correct, but the LED still doesn't turn on, it's possible the power supply fuse has blown, in this case you should contact your OMRON service center.
  • T
    tiffanyrobbinsSep 9, 2025
    Why cannot input numeric values/character strings on Omron Touch terminals?
    • P
      Phillip GouldSep 9, 2025
      If you're unable to input numeric values or character strings on your Omron Touch terminal, it could be because bit 5 of the PT status control area (numeral/character string input) is set to 1 (ON). Set bit 5 to 0 (OFF). Alternatively, the interlock function might be set for the input field, and the controlling interlock bit is OFF. Check the status of the corresponding interlock bit and turn it ON, as inputs are prohibited in input fields when the corresponding interlock bit is OFF.
  • N
    Nicholas PerezSep 13, 2025
    What does '[Backup Data Error] Memory table and History data was initialized by backup failure' mean on Omron Touch terminals?
    • C
      Charles Allen DVMSep 13, 2025
      If your Omron Touch terminal displays the message '[Backup Data Error] Memory table and History data was initialized by backup failure', it means initialization has been executed because of an error in the backup data area. Check the battery voltage by checking the color of the RUN LED and with the battery check in the System Menu; if the voltage is low, replace the battery with a new one. Re-transmit the memory table data from the Support Tool. If the voltage is normal and the problem recurs, contact your OMRON service center.
  • K
    Kevin SmithSep 23, 2025
    What does '[Programming Console Error]' mean on Omron NT31 Touch terminals and how can I fix it?
    • T
      taylorpeterSep 23, 2025
      The '[Programming Console Error]' message on your Omron Touch terminals means that the communication settings are incorrect. Set the communication method/communication port as follows when using the programming console function: With C series PLC, use NT Link : 1 : 1; with CS1 series PLC, use NT Link : 1 : N.

Omron NT31 Specifications

General IconGeneral
Display TypeSTN LCD
Touch PanelAnalog resistive
Communication InterfaceRS-232C, RS-422/485
Power Supply24 VDC
Operating Temperature0 to 50 °C
Storage Temperature-20 to 60 °C
Display Size5.7 inch
Resolution320 x 240 pixels
CPU32-bit RISC
Humidity10 to 90% RH (non-condensing)
Shock Resistance15 G for 11 ms
Protection classIP65 (front panel)