24-V power supply for output
24-V GND for output
Input common
Forward direction pulse output
(with 1.6 kΩ Resistor)
Reverse direction pulse output
(with 1.6 kΩ Resistor)
Encoder phase A+
Encoder phase A−
Encoder phase B+
Encoder phase B−
Encoder phase Z+
Encoder phase Z−
Error counter reset output
RUN output
General-purpose output
Alarm reset output
Torque limit output
Positioning completed input
General-purpose input
Alarm input
SEN output
Signal ground
24-V power supply for output
24-V GND for output
Input common
Forward direction pulse output
(with 1.6 kΩ Resistor)
Reverse direction pulse output
(with 1.6 kΩ Resistor)
Encoder phase A+
Encoder phase A−
Encoder phase B+
Encoder phase B−
Encoder phase Z+
Encoder phase Z−
Error counter reset output
RUN output
General-purpose output
Alarm reset output
Torque limit output
Positioning completed input
General-purpose input
Alarm input
SEN output
Signal ground
1
3
5
16
18
21
20
23
22
25
24
15
11
10
12
13
7
6
9
26
27
2
4
50
38
36
35
34
33
32
31
30
41
45
44
42
43
49
48
47
29
28
11 BKIR
10 BKIRCOM
3 +CW/+PULS/+FA
4
−CW/−PULS/−FA
5 +CCW/+SIGN/+FB
6 −CCW/−SIGN/−FB
21 +A
Encoder phase A+output
22 −A
Encoder phase A−output
49 +B
Encoder phase B+output
48 −B
Encoder phase B−output
23 +Z
Encoder phase Z+output
24 −Z
Encoder phase Z−output
7 +24VIN
30
ECRST
Error counter reset input
29 RUN Operation command input
26 DFSEL
Damping filter switching
31 RESET Alarm reset
27 TLSEL Torque limit switching
39 INP
38 INPCOM
35 READY
34 REDYCOM
37 /ALM
36 ALMCOM
20 SEN
13 SENGND
Shell FG Frame ground
Sensor ON input
Reverse pulses,
feed pulses, or phase A (*1)
Brake interlock output
Servo ready completed
output
Alarm output
Positioning completion
output 1
Forward pulse,
direction signal, or phase B (*1)
Red: 24 VDC
Blue: BKIRCOM
Black: 24 VDC GND
Black: BKIR
PCU side
XG4M-5030-T (OMRON)
AWG18 twisted pair 1 mAWG18 twisted pair 1 m
Servo Drive side (for axis 1 or 3)
10150-3000PE (Sumitomo 3M)
+24-V power supply for controls
*1 Since the PCU handles forward direction commands as
CW-direction/phase-A advance pulses (selectable by the
output pulse direction selection parameter), connect the wires
as shown here.