8-28
8-4 Analog Control Parameters
OMNUC G5-SERIES AC SERVOMOTOR AND SERVO DRIVE USER'S MANUAL
8
Parameter Details
If internal speed settings are enabled in the Command Speed Selection (Pn300), set the No. 1 to
4 internally set speed in Pn304 to Pn307 and the No. 5 to 8 internally set speed in Pn308 to Pn311.
Set the speed in r/min.
The polarity of the set values indicates the polarity of the internally set speed.
The absolute value of the parameter setting is limited by the Overspeed Level Setting (Pn513).
Pn310
No. 7 Internally Set Speed
Setting
range
20,000 to 20,000 Unit r/min
Default
setting
0
Power OFF
and ON
Speed
Pn311
No. 8 Internally Set Speed
Setting
range
20,000 to 20,000 Unit r/min
Default
setting
0
Power OFF
and ON
Speed
+
The forward direction as
viewed from the shaft end
The reverse direction as
viewed from the shaft end
Pn312
Soft Start Acceleration Time
Setting
range
0 to 10,000 Unit ms/(1,000 r/min)
Default
setting
0
Power OFF
and ON
Speed

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Omron OMNUC G5 R88D-KT50F and is the answer not in the manual?

Omron OMNUC G5 R88D-KT50F Specifications

General IconGeneral
BrandOmron
ModelOMNUC G5 R88D-KT50F
CategoryServo Drives
LanguageEnglish

Related product manuals