12-30
12-2 Parameter List
OMNUC G5-SERIES AC SERVOMOTOR AND SERVO DRIVE USER'S MANUAL
12
Appendix
528 Default Display
29 Drive serial number
1
0 to 35 Yes
30 Motor serial number
31 Accumulative operation time h
32 Automatic Motor Recognition Function
33 Temperature Information °C
35 Safety status monitor
531 Axis Number
Set the axis number for USB
communications. Normally, do not change
the set value.
1 0 to 127 Yes
532
Command Pulse
Input Maximum
Setting
Set the maximum command pulse input.
4000 kpps
250 to
4,000
Yes
533
Pulse
Regeneration
Limit Output
Setting
Set the detection of pulse regeneration limit error.
0 0 or 1 Yes0 Disabled
1 Enabled
535
Front Key
Protection
Setting
Set the operation limit for the front panel.
0 0 or 1 Yes0 Operation not blocked
1 Operation blocked
Pn number
Parameter
name
Description
Default
setting
Unit
Setting
range
Power
supply
OFF to
ON
Setting

Table of Contents