4.2 Component Names and Functions
122 SIEPYEUOQ2A01A AC Drive Q2A Technical Manual
Note:
Push to set d1-01 [Reference 1] when the Home screen shows U1-01 [Frequency Reference] in LOCAL Mode.
The keypad will show [Rdy] when the drive is in Drive Mode. The drive is prepared to accept a Run command.
The drive will not accept a Run command in Programming Mode in the default setting. Set b1-08 [RUN@PRG Mode Selection] to
accept or reject a Run command from an external source while in Programming Mode.
Set b1-08 = 1 [RUN@PRG Mode Selection = NoRUN@Program] to reject the Run command from an external source while in
Programming Mode (default).
Set b1-08 = 2 [RUN@PRG Mode Selection = RUN@Program] to accept the Run command from an external source while in
Programming Mode.
Set b1-08 = 3 [RUN@PRG Mode Selection = Program@Stop only] to prevent changes from Drive Mode to Programming Mode
while the drive is operating.
On the Home screen, keep pushed for 3 s to toggle between compact layout and detailed layout.