Periodic Inspection and
Maintenance
8
8.5 Replace the Drive
SIEPYEUOQ2A01A AC Drive Q2A Technical Manual 341
2. Tighten the M3 screws to a tightening torque of 0.5 Nm to 0.6 Nm (4.4 lb.in. to 5.3 lb.in.).
Figure 8.74 Safety the Terminal Block
3. Install the front cover and the keypad to their initial positions.
4. Check o2-04 [Drive KVA Selection].
Note:
When you save parameter information in a keypad that you installed before you replaced the terminal block, make sure that you use
that keypad to restore the parameter data.
To reset the performance life monitors for the components, set Maintenance Period o4-01 to o4-13.