Parameter Details
12
12.8 L: PROTECTION
SIEPYEUOQ2A01A AC Drive Q2A Technical Manual 765
When you manually clear a fault after the drive triggers protective functions.
When you re-energize the drive.
L5-02 Fault@Reset Select
No.
(Hex.)
Name Description
Default
(Range)
L5-02
(049F)
Fault@Reset Select
Sets the function that sends signals to the MFDO terminal set for Fault [H2-xx = 3] while the
drive is automatically restarting.
1
(1, 2)
1 : Disable Fault Output
2 : Enable Fault Output
L5-04 Interval Reset Time
No.
(Hex.)
Name Description
Default
(Range)
L5-04
(046C)
Interval Reset Time
Sets the time interval between each Auto Restart attempt. Set L5-05 = 1 [Reset Method =
Continuous] to enable this function.
10.0 s
(0.5 - 600.0 s)
L5-05 Reset Method
No.
(Hex.)
Name Description
Default
(Range)
L5-05
(0467)
Reset Method
Sets the count method for the Auto Restart operation.
1
(1, 2)
1 : Continuous
Counts the number of successful fault resets through Auto Restart.
When this value > L5-01, the drive will send a fault signal and fault code to the keypad and the motor will coast to
stop.
2 : Use L5-04 Time
Counts the number of successful and unsuccessful fault resets through Auto Restart. The drive does the Auto
Restart process again in the intervals set in L5-04 [Interval Reset Time].
When this value > L5-01, the drive will send a fault signal and fault code to the keypad and the motor will coast to
stop.
L5-07 OL1-4 Auto-Reset Select
No.
(Hex.)
Name Description
Default
(Range)
L5-07
(0B2A)
OL1-4 Auto-Reset Select
Use these 4 digits to set the Auto Restart function for oL1 to oL4. From left to right, the digits set
oL1, oL2, oL3, and oL4, in order.
1111
(0000 - 1111)
0 : Disabled
1 : Enabled(—/—/—/oL4)
Figure 12.134 Setting Digits and Fault Code
L5-08 U/OV,OH,GF A-Reset Select
No.
(Hex.)
Name Description
Default
(Range)
L5-08
(0B2B)
U/OV,OH,GF A-Reset
Select
Use these 4 digits to set the Auto Restart function for Uv1, ov, oH1, and GF. From left to right,
the digits set Uv1, ov, oH1, and GF, in order.
1111
(0000 - 1111)
0 : Disabled
1 : Enabled(—/–/—/GF)

Table of Contents

Other manuals for Omron Q2A Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Omron Q2A Series and is the answer not in the manual?

Omron Q2A Series Specifications

General IconGeneral
BrandOmron
ModelQ2A Series
CategoryController
LanguageEnglish

Related product manuals