EasyManua.ls Logo

Omron SYSDRIVE 3G3JV Series

Omron SYSDRIVE 3G3JV Series
166 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
7-8
Fault
display
Probable cause and remedyFault name and Meaning
ser
(flashing)
Sequence error (SER)
A sequence change has been
input while the Inverter is in
operation.
Local or remote selection is
input while the Inverter is in
operation.
Note The Inverter coasts to a
stop.
A sequence error has occurred.
Check and adjust the local or remote
selection sequence as multi-function
input.
bb
(flashing)
External base block (bb)
The external base block
command has been input.
Note The Inverter coasts to a
stop.
The external base block command has
been input as multi-function input.
Remove the cause of external base
block input.
The sequence is incorrect.
Check and change the external fault
input sequence including the input
timing and NO or NC contact.
ef
(flashing)
Forward- and reverse-rotation
input (EF)
The forward and reverse
commands are input to the
control circuit terminals
simultaneously for 0.5 s or
more.
Note The Inverter stops ac-
cording to the method set
in n04.
A sequence error has occurred.
Check and adjust the local or remote
selection sequence.
Maintenance Operations Chapter
7

Table of Contents

Related product manuals