7-8
Fault
display
Probable cause and remedyFault name and Meaning
ser
(flashing)
Sequence error (SER)
A sequence change has been
input while the Inverter is in
operation.
Local or remote selection is
input while the Inverter is in
operation.
Note The Inverter coasts to a
stop.
A sequence error has occurred.
Check and adjust the local or remote
selection sequence as multi-function
input.
bb
(flashing)
External base block (bb)
The external base block
command has been input.
Note The Inverter coasts to a
stop.
The external base block command has
been input as multi-function input.
Remove the cause of external base
block input.
The sequence is incorrect.
Check and change the external fault
input sequence including the input
timing and NO or NC contact.
ef
(flashing)
Forward- and reverse-rotation
input (EF)
The forward and reverse
commands are input to the
control circuit terminals
simultaneously for 0.5 s or
more.
Note The Inverter stops ac-
cording to the method set
in n04.
A sequence error has occurred.
Check and adjust the local or remote
selection sequence.
Maintenance Operations Chapter
7

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Omron SYSDRIVE 3G3JV Series and is the answer not in the manual?

Omron SYSDRIVE 3G3JV Series Specifications

General IconGeneral
ModelSYSDRIVE 3G3JV Series
CategoryInverter
Output Frequency Range0.1 to 400Hz
Frequency Range50/60Hz
Control MethodPWM Control
Overload Capacity150% for 1 minute
Protection FeaturesOvercurrent, Overvoltage, Undervoltage, Overheat
Cooling MethodFan Cooling
Ambient Temperature-10 to 50°C
Operating Temperature-10 to 50°C
Storage Temperature-20°C to +65°C
Humidity90% RH or less (non-condensing)
Altitude1000m or less
Vibration5.9 m/s² or less
Braking UnitBuilt-in
CommunicationRS-485
Voltage Class200V class, 400V class
Input Voltage3-phase 200 to 240V AC, 3-phase 380 to 480V AC

Related product manuals