EasyManuals Logo

Omron VARISPEED L7 User Manual

Omron VARISPEED L7
299 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #278 background imageLoading...
Page #278 background image
9-5
9
Protective structure
Enclosed wall-mounted type (IP20): All models
Enclosed wall-mounted type (NEMA 1): 18.5 kW or less (same for 200 V and 400 V class Inverters)
Open chassis type (IP00): 22 kW or more (same for 200 V and 400 V class Inverters)
Environment
Ambient operating tem-
perature
-–10°C to 45°C, max. 60°C with derating (refer to page 9-6, Ambient Temperature Derating)
Ambient operating
humidity
95% max. (with no condensation)
Storage temperature - 20°C to + 60°C (short-term temperature during transportation)
Application site Indoor (no corrosive gas, dust, etc.)
Altitude 1000 m, max. 3000 m with derating (refer to page 9-7, Altitude Derating).
Vibration
10 to 20 Hz, 9.8 m/s
2
max.; 20 to 50 Hz, 2 m/s
2
max
Regulations
Safe Disable
Hardware Baseblock meets EN954-1 safety category 3, stop category 0
EN81-1 conform one motor contactor solution possible
Harmonics EN 12015 can be fulfilled with optiona AC reactor
Table 9.3 Common Specifications
Model Number
CIMR-L7Z

Specification

Table of Contents