5-47
5
Copy Function: o3
Lift Function Parameters: S
Brake Sequence: S1
o2-10
Fan operation
time setting
Sets the initial value of the fan
operation time.
The operation time is accumu-
lated starting from this set value.
0 to
65535
0 hr. No A A A A 50EH 6-66
Fan ON Time Set
o2-12
Fault trace
initialize
0:No initialisation
1: Initialize (= zero clear) after
setting ”1“ o2-12 will be
returned to ”0“
0 or 1 0 No A A A A 510H 6-66
Fault Trace Init
o2-15
Number of Trav-
els counter initial-
ize
Operation counter initialization.
0:Number of travels counter is
kept
1: Number of travels counter
monitor clear
0 or 1 0 No A A A A 513H 6-66
Initialize Sel
Param-
eter
Num-
ber
Name
Description
Setting
Range
Factory
Setting
Change
during
Opera-
tion
Control Methods
MEMO-
BUS
Register
Page
V/f
Open
Loop
Vector
Closed
Loop
Vector
Closed
Loop
Vector
(PM)
Display
o3-01
Copy func-
tion selec-
tion
0:Normal operation
1:READ (Inverter to Operator)
2:COPY (Operator to Inverter)
3:Verify (compare)
0 to 3 0 No A A A A 515H 6-66
Copy Func-
tion Sel
o3-02
Read per-
mission
selection
0:READ prohibited
1:READ permitted
0 or 1 0 No A A A A 516H 6-66
Read
Allowable
Para-
meter
Num-
ber
Name
Description
Setting
Range
Factory
Setting
Change
during
Opera-
tion
Control Methods
MEMO-
BUS
Register
Page
V/f
Open
Loop
Vector
Closed
Loop
Vector
Closed
Loop
Vector
(PM)
Display
S1-01
Zero speed
level at stop
Sets the speed level at which the
DC injection / zero speed operation
starts during stop.
0.0 to
10.0
i
No
A
1.2
Hz
A
0.5
Hz
A
0.1 Hz
A
0.5 Hz
680H 6-13
DC Inj I @start
S1-02
DC injection
braking current
at start
Sets the DC injection braking cur-
rent as a percentage of the Inverter
rated current.
0 to
100
50% No A A - - 681H 6-39
DC Inj I @start
S1-03
DC injection
braking current
at stop
Sets the DC injection braking cur-
rent as a percentage of the Inverter
rated current.
0 to
100
50% No A A - - 682H 6-39
DC Inj I @stop
S1-04
DC injection
braking/ Zero
speed time at
start
Used to set the time to perform DC
injection braking at start in units of
1 second.
Used to stop coasting motor and
restart it. When the set value is 0,
DC injection braking at start is not
performed.
0.00
to
10.00
0.40 s No A A A A 683H 6-13
DC Inj T@start
Param-
eter
Num-
ber
Name
Description
Setting
Range
Factory
Setting
Change
during
Opera-
tion
Control Methods
MEMO-
BUS
Register
Page
V/f
Open
Loop
Vector
Closed
Loop
Vector
Closed
Loop
Vector
(PM)
Display