62
Section 4 APPENDICES
ZN
System Manual
Section 4
Specifications and Dimensions
• Calculating Unit
ZX-CAL2
Item ZX-CAL2
Available Amplifier Unit ZN-PD series, ZX series, ZJ-SD series
Current consumption 12 mA or less (supplied from the Amplifier Unit)
Ambient temperature Operating: 0 to 50°C, Storage: -15 to +60°C (with no icing or condensation)
Ambient humidity Operating and storage: 35 to 85% (with no condensation)
Connection method Connector
Dielectric strength 1,000 VAC, 50/60 Hz for 1 min
Insulation resistance 100 MΩ at 500 VDC
Vibration resistance 10 to 150 Hz, 0.7-mm double amplitude 80 min each in X, Y and Z directions
Shock resistance 300 m/s
2
3 times each in six directions (up/down, left/right, forward/backward)
Materials Display: Acrylic, Case: ABS resin
Weight (packed state) Approx. 50 g
8
12
15.1
2
4.
.
.4
24.