Scenario 1: If smoke evacuation remains poor
If the smoke evacuation is still poor after removing the accessory devices, the issue may be related
to the installation of the smoke exhaust fan.
Check the smoke
exhaust pipe
Ensure that the smoke exhaust pipe is not pressed or bent, hindering
proper smoke evacuation.
Check the installation
of the fan
Remove the smoke exhaust pipe
at the rear plate to observe if the
fan is installed correctly.
The correct installation
displays the fan blades inward.
If not, remove the fan cover
and reinstall the fan.
Scenario 2: If smoke evacuation improves
If the smoke evacuation improves after removing the accessory devices, the issue is related to the
used devices.
Check the airflow
For better smoke evacuation, make sure that your extended smoke
exhaust fan or purifier has an airflow greater than 200 cfm.
Check the filters
Remove all the filters from the purifier used for the engraver and
test the smoke evacuation. If it improves without filters, consider
replacements.
Check the extended
exhaust pipe
Confirm the smoke exhaust pipe isn’t pressed, bent, or excessively
lengthy for efficient smoke evacuation.