5 Initial Testing
5.1.3 Interlock Connector Shutoff
After ensuring that the cover and tray interlocks work properly, you should test that the remote
interlock connector functions correctly.
1. Perform the same procedure as before but, instead of opening the cover or tray, remove the
interlock connector from its socket beside the power switch.
The laser should stop completely. If it continues to engrave the design without the rear key in place,
the automatic shutoff is not working and must be repaired before the engraver can be used.
2. Turn off the machine. Contact our technical support team if the rear key shutoff is not working.