Be careful in all of the following steps not to directly touch the surface of any of
these windows, mirrors, or lenses with your finger or any dirty, oily, or abrasive
surface. Use lens-safe gloves or cloths only. Avoid pressing hard enough to cause
scratches by grinding debris into the lenses.
7.2.2 Cleaning the Camera, Mirrors, and Focus Lens
Clean the Protective Lenses
The 1st and 2nd mirrors are permanently aligned within a protective housing and should not require
adjustment or cleaning. The 3rd mirror and focus lens are held within the laser head’s protective
shell.
Clean the lenses of the protective housing’s window of the 2nd mirror using a laser-safe microfiber
cloth or a cotton swab doused in alcohol or a laser-safe cleaning solution. Clean with gentle circular
motions.
7 Maintenance
Clean the Third Mirror
1. To expose the interior of the laser head,
gently remove its shell from the magnets
that hold it in place.