5.2.6 Adding a client program to be started for the new service
Clients are local applications that may be launched when a related service is clicked. To add to the pool of
client programs:
1. Select Edit > Preferences and click the Client tab. Click Add
2. Enter a Name for the client. Enter the Path to the executable file for the client (or click Browse to
locate the executable)
3. Enter a Command Line associated with launching the client application. SDT Connector launches
a client using command line arguments to point it at the local endpoint of the redirection. There
are three special keywords for specifying the command line format. When launching the client,
SDT Connector substitutes these keywords with the appropriate values:
%path% is path to the executable file, i.e. the previous field.
%host% is the local address to which the local endpoint of the redirection is bound, i.e. the Local
Address field for the Service redirection Advanced options.
%port% is the local port to which the local endpoint of the redirection is bound, i.e. the Local TCP
Port field for the Service redirection Advanced options. If this port is unspecified (i.e. Any), the
appropriate randomly selected port is substituted.
For example, SDT Connector is preconfigured for Windows installations with a HTTP service client that
connects with whichever local browser the local Windows user has configured as the default. Otherwise
the default browser used is Firefox:

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Opengear ACM7000 and is the answer not in the manual?

Opengear ACM7000 Specifications

General IconGeneral
RS-232 ports8
SIM card slotYes
USB 2.0 ports quantity4
Number of simultaneous SIM cards2
CertificationEN 55022:2010, CISPR 22:2008, FCC Part 15 B:2015, ICES-003 5 (2014), AS/NZS CISPR 22:2009+A1:2010, EN 61000-3-2:2006/A2:2009, EN 61000-3-3:2008 EN 55024:2010, CISPR 24:2010, EN 61000-4-2:2009, EN 61000-4-3:2006+A2:2010, EN 61000-4-4:2004+A1:2010, EN 61000-4-5:2006, EN 61000-4-6:2009, EN 61000-4-8:2010, EN 61000-4-11:2004 CE, UL 1950, TUV, C-Tick, RoHS
Mounting typeRack mounting
Product colorBlack, Red
Antenna connector typeSMA
Flash memory32 MB
Internal memory256 MB
Processor frequency800 MHz
Control display unitNo
Internal memory typeDDR3
Input voltage110 - 240 V
DC input voltage12 V
Storage temperature (T-T)-40 - 75 °C
Operating temperature (T-T)-25 - 60 °C
Operating relative humidity (H-H)5 - 90 %
Security algorithmsIPSec, SSH-2, SSL/TLS
Weight and Dimensions IconWeight and Dimensions
Depth120 mm
Width130 mm
Height35 mm
Weight6000 g