7. Click Apply.
2.4 Service Access and Brute Force Protection
The administrator can access the console server and connected serial ports and managed devices using
a range of access protocols/services. For each access:
The service must first be configured and enabled to run on the console server.
Access through the firewall must be enabled for each network connection.
To enable and configure a service:
1. Click System > Services and click the Service Settings tab.
2. Enable and configure basic services:
HTTP By default, HTTP service is running and cannot be fully disabled. By default, HTTP
access is disabled on all interfaces. We recommend this access remain disabled if the
console server is accessed remotely over the Internet.
Alternate HTTP lets you to configure an alternate HTTP port to listen on. The HTTP
service will continue listening on TCP port 80 for CMS and SDT Connector
communications but will be inaccessible through the firewall.
HTTPS By default, HTTPS service is running and enabled on all network interfaces. It is
recommended that only HTTPS access be used if the console server is to be managed
over any public network. This ensures administrators have secure browser access to
all the menus on the console server. It also allows appropriately configured users
secure browser access to selected Manage menus.
The HTTPS service can be disabled or reenabled by checking HTTPS Web
Management and an alternate port specified (default port is 443).
Telnet By default the Telnet service is running but disabled on all network interfaces.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Opengear ACM7000 and is the answer not in the manual?

Opengear ACM7000 Specifications

General IconGeneral
RS-232 ports8
SIM card slotYes
USB 2.0 ports quantity4
Number of simultaneous SIM cards2
CertificationEN 55022:2010, CISPR 22:2008, FCC Part 15 B:2015, ICES-003 5 (2014), AS/NZS CISPR 22:2009+A1:2010, EN 61000-3-2:2006/A2:2009, EN 61000-3-3:2008 EN 55024:2010, CISPR 24:2010, EN 61000-4-2:2009, EN 61000-4-3:2006+A2:2010, EN 61000-4-4:2004+A1:2010, EN 61000-4-5:2006, EN 61000-4-6:2009, EN 61000-4-8:2010, EN 61000-4-11:2004 CE, UL 1950, TUV, C-Tick, RoHS
Mounting typeRack mounting
Product colorBlack, Red
Antenna connector typeSMA
Flash memory32 MB
Internal memory256 MB
Processor frequency800 MHz
Control display unitNo
Internal memory typeDDR3
Input voltage110 - 240 V
DC input voltage12 V
Storage temperature (T-T)-40 - 75 °C
Operating temperature (T-T)-25 - 60 °C
Operating relative humidity (H-H)5 - 90 %
Security algorithmsIPSec, SSH-2, SSL/TLS
Weight and Dimensions IconWeight and Dimensions
Depth120 mm
Width130 mm
Height35 mm
Weight6000 g