Chapter 4: Firewall, Failover & OOB Access
84
In this mode, Management LAN Interface is available as the transparent back-up port to Network
Interface for accessing the management network. Management LAN Interface takes over the work of
Network Interface in the event Network Interface becomes unavailable.
NOTE SSH and HTTPS access is enabled on the failover connection so an administrator can connect to
the console server and fix the problem.
By default, the console server supports automatic failure-recovery back to the original state prior to
failover (V3.1.0 firmware and later). The console server continually pings probe addresses whilst in
original and failover states. The original state is set as a priority and reestablished following three
successful pings of the probe addresses during failover. The failover state is removed once the original
state has been re-established.
4.6 Cellular Modem Connection
Some models support internal cellular modems. These modems first need to be installed and set up to
validate they can connect to the carrier network They can be configured for operation in Always- on
cellular router or OOB mode or in Failover mode.
4.6.1 Connecting to a GSM HSUPA/UMTS carrier network
-G models have an internal GSM modem that connects to any major GSM carrier globally.
1. Select Internal Cellular Modem panel on the System > Dial menu
2. Check Enable Dial-Out Settings

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Opengear ACM7000 and is the answer not in the manual?

Opengear ACM7000 Specifications

General IconGeneral
RS-232 ports8
SIM card slotYes
USB 2.0 ports quantity4
Number of simultaneous SIM cards2
CertificationEN 55022:2010, CISPR 22:2008, FCC Part 15 B:2015, ICES-003 5 (2014), AS/NZS CISPR 22:2009+A1:2010, EN 61000-3-2:2006/A2:2009, EN 61000-3-3:2008 EN 55024:2010, CISPR 24:2010, EN 61000-4-2:2009, EN 61000-4-3:2006+A2:2010, EN 61000-4-4:2004+A1:2010, EN 61000-4-5:2006, EN 61000-4-6:2009, EN 61000-4-8:2010, EN 61000-4-11:2004 CE, UL 1950, TUV, C-Tick, RoHS
Mounting typeRack mounting
Product colorBlack, Red
Antenna connector typeSMA
Flash memory32 MB
Internal memory256 MB
Processor frequency800 MHz
Control display unitNo
Internal memory typeDDR3
Input voltage110 - 240 V
DC input voltage12 V
Storage temperature (T-T)-40 - 75 °C
Operating temperature (T-T)-25 - 60 °C
Operating relative humidity (H-H)5 - 90 %
Security algorithmsIPSec, SSH-2, SSL/TLS