9.2.3 Enable NSCA monitoring
NSCA is the mechanism that allows you to send passive check results from the remote console server to
the Nagios daemon running on the monitoring server. To enable NSCA:
1. Select System > Nagios and check NSCA Enabled
2. Select the Encryption from the drop-down list and enter a Secret password and specify a check
Interval
3. See the sample Nagios configuration section below for some examples of configuring specific
NSCA checks
9.2.4 Configure selected Serial Ports for Nagios monitoring
The individual Serial Ports connected to the console server to be monitored must be configured for
Nagios checks. To enable Nagios to monitor on a device connected to the console server serial port:
1. Select Serial & Network > Serial Port and click Edit on the serial Port # to be monitored

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Opengear ACM7000 and is the answer not in the manual?

Opengear ACM7000 Specifications

General IconGeneral
RS-232 ports8
SIM card slotYes
USB 2.0 ports quantity4
Number of simultaneous SIM cards2
CertificationEN 55022:2010, CISPR 22:2008, FCC Part 15 B:2015, ICES-003 5 (2014), AS/NZS CISPR 22:2009+A1:2010, EN 61000-3-2:2006/A2:2009, EN 61000-3-3:2008 EN 55024:2010, CISPR 24:2010, EN 61000-4-2:2009, EN 61000-4-3:2006+A2:2010, EN 61000-4-4:2004+A1:2010, EN 61000-4-5:2006, EN 61000-4-6:2009, EN 61000-4-8:2010, EN 61000-4-11:2004 CE, UL 1950, TUV, C-Tick, RoHS
Mounting typeRack mounting
Product colorBlack, Red
Antenna connector typeSMA
Flash memory32 MB
Internal memory256 MB
Processor frequency800 MHz
Control display unitNo
Internal memory typeDDR3
Input voltage110 - 240 V
DC input voltage12 V
Storage temperature (T-T)-40 - 75 °C
Operating temperature (T-T)-25 - 60 °C
Operating relative humidity (H-H)5 - 90 %
Security algorithmsIPSec, SSH-2, SSL/TLS
Weight and Dimensions IconWeight and Dimensions
Depth120 mm
Width130 mm
Height35 mm
Weight6000 g