RFC 3339 This option displays a timestamp in milliseconds as well as fully qualified domain
names (FQDN), for example:
<46>2019-06-05T23:25:52.547326-04:00 syslog: [origin
software="rsyslogd" swVersion="8.33.0" x-pid="3492" x-
info="http://www.rsyslog.com"] start
11.4.2 Syslog Server Address and Port
The syslog record can be redirected to a remote Syslog Server. Enter the remote Syslog Server Address
and Syslog Server Port details and click Apply
11.4.3 Power State Changes in Syslog
For IM72xx DDC or rev6a AC models with power monitoring capabilities, power state changes are
captured in the syslog.
Voltage transitions from around 0 to around 10-13 -> emit syslog("PSU xxx power up")
Voltage transitions from around 12 to < 9 for over a period of time (lets say 5 to 10 seconds) -> emit
syslog("PSU xxx power down")
When both PSU #1 and #2 are on, the syslog reports it. For example:
14>May 7 16:57:37 psmon[2508]: INFO psmon - Internal Voltage[PSU #1] status
OPERATIONAL, value 12.025001
<14>May 7 16:57:37 psmon[2508]: INFO psmon - Internal Voltage[PSU #2] status
OPERATIONAL, value 12.050000
If PSU #1 is turned off, the syslog reports it. For example:
1
<14>May 7 16:59:08 psmon[2508]: INFO psmon - Internal Voltage[PSU #1]
status LOW, value 8.100000
If PSU #1 is turned on again, the syslog captures that. For example:
<14>May 7 16:59:23 psmon[2508]: INFO psmon - Internal Voltage[PSU #1]
status OPERATIONAL, value 12.025001
11.4.4 Syslog Match Pattern
To make it easier to find information in the local Syslog file, a pattern matching filter tool is provided.
Specify the Match Pattern that is to be searched for (e.g. the search for mount is shown below) and click
Apply. The Syslog will be represented with those entries that include the specified pattern

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Opengear ACM7000 and is the answer not in the manual?

Opengear ACM7000 Specifications

General IconGeneral
RS-232 ports8
SIM card slotYes
USB 2.0 ports quantity4
Number of simultaneous SIM cards2
CertificationEN 55022:2010, CISPR 22:2008, FCC Part 15 B:2015, ICES-003 5 (2014), AS/NZS CISPR 22:2009+A1:2010, EN 61000-3-2:2006/A2:2009, EN 61000-3-3:2008 EN 55024:2010, CISPR 24:2010, EN 61000-4-2:2009, EN 61000-4-3:2006+A2:2010, EN 61000-4-4:2004+A1:2010, EN 61000-4-5:2006, EN 61000-4-6:2009, EN 61000-4-8:2010, EN 61000-4-11:2004 CE, UL 1950, TUV, C-Tick, RoHS
Mounting typeRack mounting
Product colorBlack, Red
Antenna connector typeSMA
Flash memory32 MB
Internal memory256 MB
Processor frequency800 MHz
Control display unitNo
Internal memory typeDDR3
Input voltage110 - 240 V
DC input voltage12 V
Storage temperature (T-T)-40 - 75 °C
Operating temperature (T-T)-25 - 60 °C
Operating relative humidity (H-H)5 - 90 %
Security algorithmsIPSec, SSH-2, SSL/TLS
Weight and Dimensions IconWeight and Dimensions
Depth120 mm
Width130 mm
Height35 mm
Weight6000 g