39
Model 72 User Manual - OPEX Corporation
machine performance. For example, if uniform mail is run in varying height
mode, the shuttle will move home (center of travel) before each piece, and then
move down or up to accommodate the height of the piece. This repeated
movement is unnecessary, since the shuttle could stay in the same position.
On the other hand, if varying mail is run in fixed height mode, the shuttle does
not adjust its position before the piece arrives. When it does arrive,
adjustments will be made with the Upper and Lower Just sensors, but cycle
time will suffer.
VERIFIER OPTION
Figure 45: Verifier Option screen
The Verifier Option has three modes. Use the arrows to set the Verifier and
push Enter to save your setting.
1 VERIFIER OFF: No checking of the envelope will be made in this mode. This
setting is good for jobs with large variations in thickness between
envelopes.
2 USE FIRST ENVELOPE AS REFERENCE: This allows the first envelope to set
the standard for each envelope that follows.
3 USE 16 ENVELOPE AVERAGE AS REFERENCE: This uses a floating average of
the previous 16 envelopes as the reference. This mode allows for minor
variations in envelope thicknesses.
Verifier Voltage Change
If you are enabling the Verifier, you will be presented with an additional screen.
VERIFIER OPTION
VERIFIER OFF
USE FIRST ENVELOPE AS REFERENCE
USE 16 ENVELOPE AVERAGE AS REFERENCE