17
Conditions
Barcode Sample: OPTOELECTRONICS Test Sample
Distance
70 mm from the edge of the scanner
Label Pitch, Skew Angle, Dead Zone
PCS = 0.9, Resolution = 0.25 mm, Symbology = 9-digit Code 39,
Quiet Zone = 10 mm, N/W Ratio = 1:2.5
Tilt Angle
PCS = 0.9, Resolution = 0.26 mm, Symbology = 13-digit JAN, Quiet Zone = 10 mm
Angle Pitch Angle: Skew Angle: β = +15°, Tilt Angle: γ = 0°
Tilt Angle: Pitch Angle: α = 0°, Skew Angle: β = +1
Skew Angle, Dead Zone: Pitch Angle: α = 0°, Tilt Angle: γ = 0°
Curvature
R =
8.5. Curvature
With 8-digit JAN/UPC/EAN barcodes, decoding performance is guaranteed when
R15 mm.
With 13-digit JAN/UPC/EAN barcodes, decoding performance is guaranteed when
R20 mm.
Figure 8: Curvature
Conditions
Barcode Sample: OPTOELECTRONICS Test Sample
PCS = 0.9, Resolution = 0.26 mm, Quiet Zone = 10 mm
Distance
70 mm from the edge of the scanner
Angle
Skew Angle β = +1