14. Durability
14.1. Static Electricity
Air discharge: ±10 kV max. (No malfunction)
±15 kV max. (No destruction)
Contact discharge: ±6 kV max. (No malfunction)
±15 kV max. (No destruction)
Measurement
environment:
Use electrostatic testing device compliant with IEC 61000-4-2
Built up and discharged 15 kV of static electricity on the
scanner surface 50 times.
Discharge resistance: 330
Capacitor charging: 150 pF
14.2. Shock
14.2.1. Drop Test (without packaging)
No malfunction occurred after the following drop test.
Drop Test: Drop the scanner from a height of 150 cm onto a concrete floor (three
times in each of 5 angles).
150cm
Figure 31: Drop test
14.2.2. Drop Test (with individual packaging)
No malfunction occurred after the following drop test.
Drop Test: Drop an individually packaged scanner from a height of 150 cm onto a
concrete floor once on its 1 corner, 3 edges, and 6 sides (10 total drop tests).