Loading...
Opticon
OPR 3201
Specifications Manual
9
Figure 1: Ambient light immunity
Conditions
Barcode Sample: OPTOELECTRONICS Test Sample
PCS: 0.9
Resolution: 0.25 mm
Symbology: 9-digit Code 39
Quiet zone: 10 mm
N/W ratio: 1:2.5
Distance: 70 mm
Angle (see note below): Α = 0° β = 15° γ = 0°
Curvature: R =
Power supply voltage: 6.0 V (RS-232C)
5.0 V (Wedge/USB)
Direct light or specular reflection from a light source should be prevented from entering
the acceptance area.
Note: α, β and γ respectively represent pitch, skew and tilt. Please see section 8 for how
these values are defined.

Table of Contents