Opticon
OPR 3201
Specifications Manual
18
9. Interface Specifications
9.1. RS-232C Interface Spec
9600 bps to 115.2 kbps
9.1.1.
Settings and Communication
Reading the menu barcodes in section 11.1 can set the RS-232C interface
default.
Parameter [U2] setting
Baud rate 9600 bps
Start/stop bits 1 bit
Data bits 8 bits
Parity bits No parity
Handshaking No handshake
Flow control time out Indefinitely
Communication settings can be configured by scanning corresponding menu
barcodes.
9.1.2.
Signal Level
Signal Name I/O RS-232C Level (V)
Mark/OFF Space/ON
TxD OUT -5 to -15 +5 to +15
RxD IN -3 to -15 +3 to +15
RTS OUT -5 to -15 +5 to +15
CTS IN -3 to -15 +3 to +15